Entries 451–480 of 518
| Country | Location / Project | Medium | Temperature / Pressure | DN |
|---|---|---|---|---|
| Netherlands | Zeeuws, Horizontal drilling SIS 600/800 | Hot water (superheated) | 99 °C, PN 18 | 600/70/800 |
| Austria | Baumgarten, Kühlleitungen | Glycol-water | ohne, 6 bar | 80/-/100, 80/-/125 |
| Austria | Baumgarten, Kühlleitungen | Glycol-water | ohne, 6 bar | 80/-/100, 80/-/125 |
| Austria | Baumgarten, Österreich Kühlleitungen | Glycol-water mixture | -25 °C bis +50 °C | 80/0/100 |
| Austria | Baumgarten, Österreich, Erdgaskondensat | Natural gas condensate | 50 °C, 29 bar | 50/0/80 |
| Austria | Baumgarten, Ruden | Oil | 70°C, 12 bar | 50/0/80 |
| Austria | Breitfeld | Steam | 180 °C, 10 bar | 65/40/200 |
| Austria | Dürnrohr, Bioethanolanlage | Steam | 210 °C, 18 bar | 350/100/600, 500/120/800 |
| Austria | Dürnrohr, Frischdampfleitung AVN | Steam | 400 °C, 57 bar / 210 °C, 19 bar | 200/100/500, 300/165/700, 350/100/700, 400/100/700 |
| Austria | Klagenfurt, Klinikum | Steam | 210 °C, 19 bar | 150/90/400 |
| Austria | Leitung Schichtenspeicher | Hot water (superheated) | 130 °C, PN 10 | 300/50/450 |
| Austria | Mondsee, Heißwasserleitung | Hot water (superheated) | 170°C, 12 bar | 125/45/250 |
| Austria | Neustift, Österreich, Kühlleitung | Glycol-water mixture | 20 °C bis +50 °C, 6 bar | 80/0/100 |
| Austria | Österreich, WAG Plus 600 - Phase II Si-Rohr | Natural gas condensate | 50 °C, 29 bar | 50/80, 80/150 |
| Austria | Salzburg, Landeskrankenhaus-HKW | Hot water (superheated) | 180 °C, 25 bar | 200/70/600 |
| Austria | Salzburg, mehrere Baulose | Steam | 200 °C, 16 bar | 400/110/700, 350/90/600, 250/80/500, 150/60/350, 65/50/200 |
| Austria | Salzburg, Ringschluss Krankenhaus | Hot water (superheated) | 200 °C, PN 16, 13 bar | 200/110/500 |
| Austria | Salzburg, Schutzrohrstrecke | Hot water (superheated) | 130 °C, 13 bar | 600/100/900 |
| Austria | Salzburg, Schutzrohrstrecke | Hot water (superheated) | 130 °C, PN 16 | 600/100/900 |
| Austria | Salzburg, Wallnergasse | Steam | 200 °C, 16 bar | 350/90/600-700 |
| Poland | Andropol, Steam pipeline | Steam | 220 °C, 6 bar | 200/80/500-600 |
| Poland | Bialystok, Biaform | Steam | 225 °C, PN 25 | 150/80/400 |
| Poland | Bialystok, Brauerei | Steam | 225 °C, PN 25 | 300/110/650 |
| Poland | Bielsko-Biala | Steam | 250 °C, PN 25 | 500/800 |
| Poland | Bielsko-Biala | Steam | 300 °C, PN 25 | 600 |
| Poland | Bielsko, Przebudowa, Parodagu/City Cieszyn | Steam | 220 °C, 13 bar | 65/90/300 |
| Poland | Poznan | Steam | 200 °C, PN 16 | 125/60/300 |
| Poland | Poznan, Waste water treatment plant | Steam | 180 °C, 6 bar | 65/40/200 |
| Schweiz, Italien | Basel, Schweiz | Thermal oil (heat transfer fluid) | 200 °C, PN 16 | II-RF 80-80/50-50/450 |
| Schweiz, Italien | Bern, Hausanschluss von Roll | Steam | 200°C, 24 bar | 100/50/250 |