Entries 151–180 of 518

Country Location / Project Medium Temperature / Pressure DN
Germany Frankfurt/Main Steam 180 °C, 9 bar 350/90/600-700
Germany Frankfurt/Main Geb. 825 Steam / condensate 200 °C, 4 bar 25/30/125, 80/40/200, 100/50/250
Germany Frankfurt/Main Neue Mainzer Str. Steam 220°C, 16 bar 100/70/300
Germany Frankfurt/Main, Alte Rothofstraße Steam 220 °C, 5 bar 65/50/250, 80/40/250, 150/70/400
Germany Frankfurt/Main, Anschluss Frankfurter Rundschau Steam 220 °C, 5 bar 80/80/300, 250/50+60/600
Germany Frankfurt/Main, Baufeld 13.2 Steam 250 °C, PN 16 32/30/150, 40/30/150, 80/50/250, 125/60/300
Germany Frankfurt/Main, Börsenstraße Steam 220 °C, PN 16 125/100/400
Germany Frankfurt/Main, Goethehaus Steam 220 °C, 5 bar 500/150/900
Germany Frankfurt/Main, Infraserv Steam / condensate 300 °C, 16 bar / 200 °C, 6 bar / 100 °C, 16 bar 50/30/150, 80/90/300, 200/80/450
Germany Frankfurt/Main, Infraserv H811 Condensate 100°C, 25 bar / 200°C, 3,2 bar / 300°C, 16,5 bar 50/30/150, 300/110/600, 100/110/400
Germany Frankfurt/Main, Klinikum 2.BA Steam / condensate 200°C, 9 bar 50/50/200, 32/30/150
Germany Frankfurt/Main, Lange Straße 30 - 36 Steam 225 °C, 5 bar 250/110/550
Germany Frankfurt/Main, Neue Mainzer Str. Steam 220°C, 16 bar 125/80/350, 150/110/800, 40/110/1000
Germany Frankfurt/Main, Ticona, Kondensatltg. Condensate 130 °C, 25 bar 250/40/400
Germany Freiburg, Fraunhofer-Institut Steam 180 °C, PN 16 125/60/300
Germany Friedberg/Hessen Steam 170 °C, PN 25 25-250
Germany Fürstenwalde, Reifenwerk Pneumant Steam 200 °C, 30 bar 125/100/400
Germany Gelnhausen, Coleman-Kaserne, Abzweig Hot water (superheated) 130 °C, PN 16 100-100/30-30/450
Germany Gera Steam 210 °C, PN 16 700/150/1100
Germany Gera, Regenüberlaufbecken Am Stadion Steam 220 °C, 15 bar 600/150/1000
Germany Gera, Westtangente Fridericistraße Steam 220 °C, 15 bar 600/160/1000-1100
Germany Gießen, TREA Steam 240 °C, 26 bar 80/80/300
Germany Göttingen, 2trasse Göttingen Steam 200 °C, PN 16 50/50/200, 150/70/350
Germany Göttingen, Uni, Forschungszentrum Steam 145 °C, 25 bar 300/90/550
Germany Grafenwöhr, Camp East Geb. 347 Hot water (superheated) 160 °C, 25 bar 80/40/300
Germany Grafenwöhr, FGL Bayreuth, Camp East Hot water (superheated) 160 °C, PN 25 125/40/250-400
Germany Großenlüder Carpet adhesive 300 °C, PN 25 150
Germany Großenlüder Carpet adhesive 300 °C, PN 25 150/200, 200/250
Germany Guben Hot water (superheated) 150 °C, PN 16 250
Germany Hagen, Knippschildstr. Austausch Kanalleitung Hot water (superheated) 200°C, 23 bar 200/70/400