Entries 211–240 of 518

Country Location / Project Medium Temperature / Pressure DN
Germany Höchst/Odenwald Steam / condensate 230 °C, 23 bar / 90 °C, PN 16 150/90/400, 50/40/200
Germany Homburg/Saar Steam 180/100 °C, PN 25 250
Germany Idar-Oberstein Steam 200 °C, PN 25 150-650
Germany Illertissen Steam 200 °C, PN 25 150/60/350
Germany Illertissen Steam 200 °C, PN 25 50/50/200-200/90/450
Germany Kaiserslautern Hot water (superheated) 180 °C, PN 25 300/90/600
Germany Kaiserslautern-Vogelweh Hot water (superheated) 160 °C, PN 25 200/80/450
Germany Kaiserslautern, Kaiserslautern SRS Hot water (superheated) 130 °C, 5 bar 200/40/600, 300/90/600
Germany Kälteleitung Ammonia -20 °C/+ 30 °C, 13 bar 200/60/400, 80/50/250
Germany Kassel Hot water (superheated) 140 °C, PN 25 550
Germany Kassel, Energiezentrale Mittelfeld Steam 220 °C, 10 bar 400/120/700-1000
Germany Kelsterbach Steam 300 °C, 18 bar 100/70/300
Germany Kiel Steam 170 °C, PN 25 300/350
Germany Kiel Hot water (superheated) 160/100 °C, PN 25 80
Germany Kiel, Abwasserkanal, Si-Rohr Wastewater ohne 1000/1400
Germany Kiel, Hagenuk Steam 180 °C, PN 16 400
Germany Kitzingen Hot water (superheated) 170 °C, PN 25 250
Germany Kitzingen Hot water (superheated) 170 °C, PN 25 50-150
Germany Kitzingen, Harvey-Kaserne Hot water (superheated) 160 °C, PN 25 80-80/60-60/500
Germany Kitzingen, Umverlegung Halle 66 Hot water (superheated) 160 °C, 14 bar 125-125/70-50/60, 25-25/20-20/250
Germany Kloster Ettal Steam 184 °C, 11 bar 125/50/300
Germany Koblenz, Adapter Bundeswehr, Si-Rohr Fuel 20 °C, PN 100 DN 150
Germany Koblenz, Ferdinand-Sauerbruch-Str. Hot water (superheated) 180°C, 20 bar 200/60/400
Germany Köln Niehl Heating oil (fuel oil) 50 °C, 6 bar 250/300, 200/250
Germany Köln, Eislaufstadion Ammonia -20 °C bis +40 °C, 13 bar 50/50/200, 65/50/200, 100/50/250
Germany Lauta, Rygol Dämmstoffe Steam 300 °C, 14 bar 50/70/300, 125/130/450
Germany Lauterbach, 2leitung Heggenstaller Steam 220 °C, 20 bar 80/60/250
Germany Leipzig Umformstation Hot water (superheated) 140 °C, PN 25 150/50/300
Germany Leipzig, Telekom Hot water (superheated) 180 °C, PN 25 80
Germany Leverkusen Wastewater / acid condensate / NaOH / mother liquor 300 °C, PN 25 25/100